Excellent Electrical Insulation
- Voltage ratings: 1KV, 10KV, 35KV, catering to diverse voltage scenarios.
- Breakdown voltage: ≥35KV/mm, ensuring safe operation in high-voltage environments.
- Insulation resistance: ≥10¹⁴ Ω·cm, effectively isolating contaminants and preventing leakage.
Good Flame Retardancy and Safety
- Shrink ratio: 2:1 or 3:1 (radial shrinkage ≥50%), ensuring tight adherence to busbar surfaces.
- Shrinkage temperature: starts at 80℃, fully shrinks at 120℃, with fast shrinkage speed.
- Continuous operating temperature: -55℃~105℃, suitable for extreme climates.
- Tensile strength: ≥10.5 N/mm², with high tear resistance to prevent installation damage.
Environmental & Chemical Resistance
- Chemical resistance: withstands acid, alkali, and salt corrosion, extending busbar lifespan.
- Moisture & dust resistance: dense insulation layer prevents water vapor and dust ingress, maintaining stable electrical performance.
- Animal protection: prevents short circuits caused by rodents or snakes.
Safety & Compliance
- Flame retardancy: UL 224 certified, meeting VW-1 standards for fire safety.
- Environmental compliance: ROHS 2.0 compliant, lead-free and halogen-free, supporting sustainability.
Technical Specifications
| Parameter | Value |
|---|---|
| Material | Radiation-Crosslinked Polyolefin |
| Color | Red, Yellow, Green |
| Density | 1.2 g/cm³ |
| Water Absorption | ≤0.5% |
| Certification Standard | UL 224, ROHS 2.0, IEC 60811-1-1 |
Applications
- Substation busbar protection: reduces phase spacing, preventing short circuits and accidental electric shocks.
- High/low-voltage switchgear: offers insulation, anti-rust, and mechanical protection, adapting to miniaturization trends.
- Industrial equipment: safeguards busbar connections in motors, transformers, etc.
Installation Instructions
Preparation Steps
- Clean busbar surfaces to remove oil and dust.
- Select tubing size based on busbar dimensions.
Shrinkage Operation
- Heat with a heat gun or oven at 120℃~140℃ until fully shrunk.
- Avoid localized overheating to prevent material degradation.
Quality Inspection
- Post-shrinkage inspection: ensure no wrinkles or bubbles; insulation thickness deviation ≤±10%.
- For irregular busbar joints, use custom tubing for segmented protection.
Packaging & Storage
- Packaging: coiled or straight-cut, 50 meters per roll, sealed in moisture-proof bags.
- Storage conditions: -20℃~30℃, relative humidity <70%, avoid direct sunlight.
Key Advantages Summary
- Compact design: reduces phase spacing, enhancing space efficiency.
- Full environmental protection: moisture, dust, corrosion, and animal-resistant.
- Safety compliance: UL, ROHS certified, ensuring electrical safety.
- Easy installation: fast shrinkage, simplifying construction.
Performance Parameter
| Test Item | Test Method | Test Value |
|---|---|---|
| Tensile Strength | ASTM D638 | ≥ 12MPA |
| Breakage Elongation | ASTM D638 | ≥ 300% |
| Tensile Strength after aging | ASTM D638 | ≥ 10MPA |
| Elongation after aging | ASTM D638 | ≥ 220% |
| Longitudinal Shrink Ratio | ASTM D2671 | ±5% |
| Dielectric Constant | ASTM D2671 | ≥ 18 Ω·CM |
| Breakdown Strength | ASTM D149 | ≥ 25KV/MM |
| Volume Resistivity | ASTM D257 | 10¹⁴ Ω·CM |
| Volume Resistivity at 20℃ | ASTM D257 | 10¹⁴ Ω·CM |
| Oxygen Index | ASTM D2863 | ≥ 26% |
| Water Absorption | ASTM D570 | ≤ 0.2% |
| Density | ASTM D792 | 1.25 G/CM³ |
| Eccentricity | ASTM D792 | 30% |
| Fully Contraction Temperature Ratio | ASTM D792 | 130±5℃ |
| Test Item | Test Method | Test Value |
|---|---|---|
| Tensile Strength | ASTM D638 | ≥ 13MPA |
| Breakage Elongation | ASTM D638 | ≥ 450% |
| Tensile Strength after aging | ASTM D638 | ≥ 12MPA |
| Elongation after aging | ASTM D638 | ≥ 400% |
| Longitudinal Shrink Ratio | ASTM D2671 | ±5% |
| Dielectric Constant | ASTM D2671 | ≥ 18 Ω·CM |
| Breakdown Strength | ASTM D149 | ≥ 25KV/MM |
| Volume Resistivity | ASTM D257 | 10¹⁴ Ω·CM |
| Volume Resistivity at 20℃ | ASTM D257 | 10¹⁴ Ω·CM |
| Oxygen Index | ASTM D2863 | ≥ 30% |
| Water Absorption | ASTM D570 | ≤ 0.2% |
| Density | ASTM D792 | 1.25 G/CM³ |
| Eccentricity | ASTM D792 | 30% |
| Fully Contraction Temperature Ratio | ASTM D792 | 130±5℃ |
Product Specification Sheet
| Specification | Before Contraction | After Contraction | Packing Method | ||
|---|---|---|---|---|---|
| Inner Diameter (MM) | Wall Thickness (MM) | Inner Diameter (MM) | Wall Thickness (MM) | ||
| LMPG-10-φ12/6 | 12±0.1 | 0.63±0.05 | 12±0.1 | 1.25±0.05 | 25M/Roll |
| LMPG-10-φ16/8 | 16±0.1 | 0.75±0.05 | 16±0.1 | 1.5±0.05 | 25M/Roll |
| LMPG-10-φ20/10 | 20±0.1 | 0.80±0.05 | 20±0.1 | 1.6±0.05 | 25M/Roll |
| LMPG-10-φ25/12.5 | 25±0.1 | 0.85±0.05 | 25±0.1 | 1.75±0.05 | 25M/Roll |
| LMPG-10-φ30/15 | 30±0.1 | 0.90±0.05 | 30±0.1 | 1.85±0.05 | 25M/Roll |
| LMPG-10-φ40/20 | 40±0.1 | 0.98±0.05 | 40±0.1 | 2.0±0.05 | 25M/Roll |
| LMPG-10-φ50/25 | 50±0.1 | 0.98±0.05 | 50±0.1 | 2.0±0.05 | 25M/Roll |
| LMPG-10-φ60/30 | 60±0.1 | 1.05±0.05 | 60±0.1 | 2.1±0.05 | 25M/Roll |
| LMPG-10-φ70/35 | 70±0.1 | 1.05±0.05 | 70±0.1 | 2.1±0.05 | 25M/Roll |
| LMPG-10-φ80/40 | 80±0.1 | 1.15±0.05 | 80±0.1 | 2.3±0.05 | 25M/Roll |
| LMPG-10-φ90/45 | 90±0.1 | 1.15±0.05 | 90±0.1 | 2.3±0.05 | 25M/Roll |
| LMPG-10-φ100/50 | 100±0.1 | 1.20±0.05 | 100±0.1 | 2.4±0.05 | 25M/Roll |
| LMPG-10-φ120/60 | 120±0.1 | 1.25±0.05 | 120±0.1 | 2.5±0.05 | 25M/Roll |
| LMPG-10-φ150/75 | 150±0.1 | 1.25±0.05 | 150±0.1 | 2.5±0.05 | 25M/Roll |
| LMPG-10-φ180/90 | 180±0.1 | 1.30±0.05 | 180±0.1 | 2.6±0.05 | 25M/Roll |
| Specification | Before Contraction | After Contraction | Packing Method | ||
|---|---|---|---|---|---|
| Inner Diameter (MM) | Wall Thickness (MM) | Inner Diameter (MM) | Wall Thickness (MM) | ||
| LMPG-35-φ30/15 | 30±0.1 | 1.46±0.05 | 30±0.1 | 3.0±0.05 | 20M/Roll |
| LMPG-35-φ40/20 | 40±0.1 | 1.46±0.05 | 40±0.1 | 3.0±0.05 | 20M/Roll |
| LMPG-35-φ50/25 | 50±0.1 | 1.46±0.05 | 50±0.1 | 3.2±0.05 | 20M/Roll |
| LMPG-35-φ60/30 | 60±0.1 | 1.60±0.05 | 60±0.1 | 3.2±0.05 | 20M/Roll |
| LMPG-35-φ70/35 | 70±0.1 | 1.60±0.05 | 70±0.1 | 3.2±0.05 | 20M/Roll |
| LMPG-35-φ80/40 | 80±0.1 | 1.60±0.05 | 80±0.1 | 3.2±0.05 | 20M/Roll |
| LMPG-35-φ90/45 | 90±0.1 | 1.60±0.05 | 90±0.1 | 3.2±0.05 | 20M/Roll |
| LMPG-35-φ100/50 | 100±0.1 | 1.60±0.05 | 100±0.1 | 3.2±0.05 | 20M/Roll |
| LMPG-35-φ120/60 | 120±0.1 | 1.65±0.05 | 120±0.1 | 3.3±0.05 | 20M/Roll |
| LMPG-35-φ150/75 | 150±0.1 | 1.65±0.05 | 150±0.1 | 3.3±0.05 | 20M/Roll |
| LMPG-35-φ180/90 | 180±0.1 | 1.65±0.05 | 180±0.1 | 3.3±0.05 | 20M/Roll |
Frequently Asked Questions
What voltage ratings does this busbar heat shrink tubing support?
The heat shrink tubing is available in voltage ratings of 1KV, 10KV, and 35KV, with breakdown voltage ratings of ≥25KV/mm to ≥35KV/mm to satisfy diverse low to medium/high-voltage electrical cabinet and substation requirements.
What is the recommended shrinkage temperature for optimal installation?
Shrinkage starts at 80℃ and achieves full contraction at 120℃~140℃ using an industrial heat gun or heating oven. Uniform heating without localized overheating is advised to avoid degradation.
What material standards and certifications does the tubing comply with?
Made of high-grade radiation-crosslinked polyolefin, the product complies with UL 224 (VW-1 flame retardant), RoHS 2.0 (lead-free, halogen-free), and IEC 60811-1-1 international testing standards.
How does the tubing protect against environmental and physical threats?
It provides reliable resistance against moisture, dust, chemical acids, alkali, and salt corrosion. Additionally, the dense protective sleeve safeguards busbar systems from flashovers caused by rodents, snakes, or small animals.
What is the continuous operating temperature range of this tubing?
The tubing operates reliably in extreme working environments from -55℃ to +105℃, maintaining superior mechanical strength and insulation integrity.
What are the recommended storage requirements?
It should be stored sealed in moisture-proof bags at temperatures between -20℃ and 30℃ with relative humidity under 70%, away from direct heat and sunlight.