Leave Your Message
High-Performance Busbar Heat Shrink Tube from China Factory - Quality Insulation from Trusted Suppliers
Hot Products

High-Performance Busbar Heat Shrink Tube from China Factory - Quality Insulation from Trusted Suppliers

,

Product Overview

,

Introducing our premium busbar heat shrink tubing, an essential electrical insulation solution specifically designed for substations and both high and low-voltage switchgear busbars. Manufactured in China by leading suppliers, this innovative product is crafted from radiation-crosslinked polyolefin, which allows for a more compact layout by minimizing phase spacing. Our busbar heat shrink tubing not only ensures excellent insulation but also provides robust protection against moisture, dust, and corrosion, making it a reliable choice for any electrical system. Trust our factory to deliver high-quality insulation solutions that meet your needs.

,
  • Material: (Radiation-Crosslinked Polyolefin)
  • Color: (Red, Yellow, Green)
  • Density: 1.2 g/cm³
  • Water Absorption: ≤0.5%
  • Certification Standard: UL 224, ROHS 2.0, IEC 60811-1-1

Product Features

  • Excellent Electrical Insulation

    • Voltage ratings: 1KV, 10KV, 35KV, catering to diverse voltage scenarios.
    • Breakdown voltage: ≥35KV/mm, ensuring safe operation in high-voltage environments.
    • Insulation resistance: ≥10¹⁴ Ω·cm, effectively isolating contaminants and preventing leakage.

  • 🔥 Good Flame Retardancy and Safety

    • Shrink ratio: 2:1 or 3:1 (radial shrinkage ≥50%), ensuring tight adherence to busbar surfaces.
    • Shrinkage temperature: starts at 80℃, fully shrinks at 120℃, with fast shrinkage speed.
    • Continuous operating temperature: -55℃~105℃, suitable for extreme climates.
    • Tensile strength: ≥10.5 N/mm², with high tear resistance to prevent installation damage.

  • 🛡️ Environmental & Chemical Resistance

    • Chemical resistance: withstands acid, alkali, and salt corrosion, extending busbar lifespan.
    • Moisture & dust resistance: dense insulation layer prevents water vapor and dust ingress, maintaining stable electrical performance.
    • Animal protection: prevents short circuits caused by rodents or snakes.

  • Safety & Compliance

    • Flame retardancy: UL 224 certified, meeting VW-1 standards for fire safety.
    • Environmental compliance: ROHS 2.0 compliant, lead-free and halogen-free, supporting sustainability.

Technical Specifications

Parameter Value
Material Radiation-Crosslinked Polyolefin
Color Red, Yellow, Green
Density 1.2 g/cm³
Water Absorption ≤0.5%
Certification Standard UL 224、ROHS 2.0、IEC 60811-1-1

Applications

◎ Substation busbar protection: reduces phase spacing, preventing short circuits and accidental electric shocks.
◎ High/low-voltage switchgear: offers insulation, anti-rust, and mechanical protection, adapting to miniaturization trends.
◎ Industrial equipment: safeguards busbar connections in motors, transformers, etc.

Applications1
Applications2
Applications3

Installation Instructions

  • 🔧 Preparation Steps

    • Clean busbar surfaces to remove oil and dust.
    • Select tubing size based on busbar dimensions.

  • 🌡️ Shrinkage Operation

    • Heat with a heat gun or oven at 120℃~140℃ until fully shrunk.
    • Avoid localized overheating to prevent material degradation.

  • 🔍 Quality Inspection

    • Post-shrinkage inspection: ensure no wrinkles or bubbles; insulation thickness deviation ≤±10%.
    • For irregular busbar joints, use custom tubing for segmented protection.

Packaging & Storage

◎ Packaging: coiled or straight-cut, 50 meters per roll, sealed in moisture-proof bags.
◎ Storage conditions: -20℃~30℃, relative humidity <70%, avoid direct sunlight.

Key Advantages Summary

📐
Compact DesignReduces phase spacing, enhancing space efficiency.
🌧️
Full Environmental ProtectionMoisture, dust, corrosion, and animal-resistant.
🏅
Safety ComplianceUL, ROHS certified, ensuring electrical safety.
⚙️
Easy InstallationFast shrinkage, simplifying construction.

Performance Parameter

Test Item Test Method Test Value
Tensile Strength ASTM D638 ≥ 12MPA
Breakage Elongation ASTM D638 ≥ 300%
Tensile Strength after aging ASTM D638 ≥ 10MPA
Elongation after aging ASTM D638 ≥220%
Longitudinal Shrink Ratio ASTM D2671 ±5%
Dielectric Constant ASTM D2671 ≥ 18Ω.CM
Breakdown Strength ASTM D149 ≥ 25KV/MM
Volume Resistivity ASTM D257 10¹⁴Ω.CM
Volume Resistivity at 20℃ ASTM D257 10¹⁴Ω.CM
Oxygen Index ASTM D2863 ≥ 26%
Water Absorption ASTM D570 ≤0.2%
Density ASTM D792 1.25G/CM³
Eccentricity ASTM D792 30%
Fully Contraction Temperature Ratio ASTM D792 130±5℃
Test Item Test Method Test Value
Tensile Strength ASTM D638 ≥ 13MPA
Breakage Elongation ASTM D638 ≥ 450%
Tensile Strength after aging ASTM D638 ≥ 12MPA
Elongation after aging ASTM D638 ≥400%
Longitudinal Shrink Ratio ASTM D2671 ±5%
Dielectric Constant ASTM D2671 ≥ 18Ω.CM
Breakdown Strength ASTM D149 ≥ 25KV/MM
Volume Resistivity ASTM D257 10¹⁴Ω.CM
Volume Resistivity at 20℃ ASTM D257 10¹⁴Ω.CM
Oxygen Index ASTM D2863 ≥ 30%
Water Absorption ASTM D570 ≤0.2%
Density ASTM D792 1.25G/CM³
Eccentricity ASTM D792 30%
Fully Contraction Temperature Ratio ASTM D792 130±5℃

Product Specification Sheet

Specification Before Contraction After Contraction Packing Method
Inner Diameter (MM) Wall Thickness (MM) Inner Diameter (MM) Wall Thickness (MM)
LMPG-10-φ12/6 12±0.1 0.63±0.05 12±0.1 1.25±0.05 25M/Roll
LMPG-10-φ16/8 16±0.1 0.75±0.05 16±0.1 1.5±0.05 25M/Roll
LMPG-10-φ20/10 20±0.1 0.80±0.05 20±0.1 1.6±0.05 25M/Roll
LMPG-10-φ25/12.5 25±0.1 0.85±0.05 25±0.1 1.75±0.05 25M/Roll
LMPG-10-φ30/15 30±0.1 0.90±0.05 30±0.1 1.85±0.05 25M/Roll
LMPG-10-φ40/20 40±0.1 0.98±0.05 40±0.1 2.0±0.05 25M/Roll
LMPG-10-φ50/25 50±0.1 0.98±0.05 50±0.1 2.0±0.05 25M/Roll
LMPG-10-φ60/30 60±0.1 1.05±0.05 60±0.1 2.1±0.05 25M/Roll
LMPG-10-φ70/35 70±0.1 1.05±0.05 70±0.1 2.1±0.05 25M/Roll
LMPG-10-φ80/40 80±0.1 1.15±0.05 80±0.1 2.3±0.05 25M/Roll
LMPG-10-φ90/45 90±0.1 1.15±0.05 90±0.1 2.3±0.05 25M/Roll
LMPG-10-φ100/50 100±0.1 1.20±0.05 100±0.1 2.4±0.05 25M/Roll
LMPG-10-φ120/60 120±0.1 1.25±0.05 120±0.1 2.5±0.05 25M/Roll
LMPG-10-φ150/75 150±0.1 1.25±0.05 150±0.1 2.5±0.05 25M/Roll
LMPG-10-φ180/90 180±0.1 1.30±0.05 180±0.1 2.6±0.05 25M/Roll
Specification Before Contraction After Contraction Packing Method
Inner Diameter (MM) Wall Thickness (MM) Inner Diameter (MM) Wall Thickness (MM)
LMPG-35-φ30/15 30±0.1 1.46±0.05 30±0.1 3.0±0.05 20M/Roll
LMPG-35-φ40/20 40±0.1 1.46±0.05 40±0.1 3.0±0.05 20M/Roll
LMPG-35-φ50/25 50±0.1 1.46±0.05 50±0.1 3.2±0.05 20M/Roll
LMPG-35-φ60/30 60±0.1 1.60±0.05 60±0.1 3.2±0.05 20M/Roll
LMPG-35-φ70/35 70±0.1 1.60±0.05 70±0.1 3.2±0.05 20M/Roll
LMPG-35-φ80/40 80±0.1 1.60±0.05 80±0.1 3.2±0.05 20M/Roll
LMPG-35-φ90/45 90±0.1 1.60±0.05 90±0.1 3.2±0.05 20M/Roll
LMPG-35-φ100/50 100±0.1 1.60±0.05 100±0.1 3.2±0.05 20M/Roll
LMPG-35-φ120/60 120±0.1 1.65±0.05 120±0.1 3.3±0.05 20M/Roll
LMPG-35-φ150/75 150±0.1 1.65±0.05 150±0.1 3.3±0.05 20M/Roll
LMPG-35-φ180/90 180±0.1 1.65±0.05 180±0.1 3.3±0.05 20M/Roll

Make a Free Consultant

Your Name *

E-mail *

Phone Number

Country

Remarks *

Frequently Asked Questions

What voltage ratings are available for busbar heat shrink tubing?
Our busbar heat shrink tubing is available in three voltage ratings: 1KV, 10KV, and 35KV, making it suitable for a wide range of low, medium, and high-voltage applications including substations, switchgear, and industrial equipment.
What is the correct shrinkage temperature for installation?
Shrinkage begins at approximately 80℃ and the tubing fully shrinks at 120℃. During installation, heat evenly using a heat gun or oven at 120℃ to 140℃. Avoid localized overheating to prevent material degradation or surface damage.
Is this busbar heat shrink tubing compliant with international safety standards?
Yes. The tubing meets UL 224 certification with VW-1 flame retardancy rating and is fully ROHS 2.0 compliant, ensuring it is lead-free and halogen-free. It also conforms to IEC 60811-1-1 standards for electrical insulation materials.
Can the tubing withstand harsh environmental conditions?
Absolutely. The radiation-crosslinked polyolefin material provides excellent resistance to acid, alkali, salt corrosion, moisture, and dust. It also offers animal protection against rodents and snakes, and operates reliably across a continuous temperature range of -55℃ to 105℃.
What shrink ratios are available and how do I select the right size?
The tubing is available in 2:1 and 3:1 shrink ratios with radial shrinkage ≥50%. To select the right size, measure the outer diameter of your busbar and choose a tubing inner diameter that is slightly larger before shrinkage. Refer to our Product Specification Sheet for the full range of available inner diameters from φ12 to φ180mm.
How should the busbar heat shrink tubing be stored?
Store the tubing in a cool, dry environment at temperatures between -20℃ and 30℃ with relative humidity below 70%. Keep away from direct sunlight and heat sources. Tubing is supplied coiled or straight-cut, 50 meters per roll, sealed in moisture-proof packaging.