Introducing our Busbar Heat Shrink Tubing, an essential electrical insulation solution crafted for substations and high/low-voltage switchgear busbars. Manufactured from high-quality radiation-crosslinked polyolefin in our state-of-the-art factory in China, this innovative product facilitates a compact layout by minimizing phase spacing. Our busbar heat shrink tubing not only ensures superior moisture, dust, and corrosion protection but also stands out as a reliable choice among suppliers in the industry.

,
  • Material: (Radiation-Crosslinked Polyolefin)
  • Color: (Red, Yellow, Green)
  • Density: 1.2 g/cm³
  • Water Absorption: ≤0.5%
  • Certification Standard: UL 224, ROHS 2.0, IEC 60811-1-1

Product Features
  • ◎ Excellent Electrical Insulation

    • Voltage ratings: 1KV, 10KV, 35KV, catering to diverse voltage scenarios.
    • Breakdown voltage: ≥35KV/mm, ensuring safe operation in high-voltage environments.
    • Insulation resistance: ≥10¹⁴ Ω·cm, effectively isolating contaminants and preventing leakage.

  • ◎ Good Flame Retardancy and Safety

    • Shrink ratio: 2:1 or 3:1 (radial shrinkage ≥50%), ensuring tight adherence to busbar surfaces.
    • Shrinkage temperature: starts at 80℃, fully shrinks at 120℃, with fast shrinkage speed.
    • Continuous operating temperature: -55℃~105℃, suitable for extreme climates.
    • Tensile strength: ≥10.5 N/mm², with high tear resistance to prevent installation damage.

  • ◎ Environmental & Chemical Resistance

    • Chemical resistance: withstands acid, alkali, and salt corrosion, extending busbar lifespan.
    • Moisture & dust resistance: dense insulation layer prevents water vapor and dust ingress, maintaining stable electrical performance.
    • Animal protection: prevents short circuits caused by rodents or snakes.

  • ◎ Safety & Compliance

    • Flame retardancy: UL 224 certified, meeting VW-1 standards for fire safety.
    • Environmental compliance: ROHS 2.0 compliant, lead-free and halogen-free, supporting sustainability.

Technical Specifications
Parameter Value
Material Radiation-Crosslinked Polyolefin
Color Red, Yellow, Green
Density 1.2 g/cm³
Water Absorption ≤0.5%
Certification Standard UL 224、ROHS 2.0、IEC 60811-1-1
Applications
  • ◎ Substation busbar protection: reduces phase spacing, preventing short circuits and accidental electric shocks.
    ◎ High/low-voltage switchgear: offers insulation, anti-rust, and mechanical protection, adapting to miniaturization trends.
    ◎ Industrial equipment: safeguards busbar connections in motors, transformers, etc.

Applications1
Applications2
Applications3
Installation Instructions
  • 1 ◎ Preparation Steps

    • Clean busbar surfaces to remove oil and dust.
    • Select tubing size based on busbar dimensions.

  • 2 ◎ Shrinkage Operation

    • Heat with a heat gun or oven at 120℃~140℃ until fully shrunk.
    • Avoid localized overheating to prevent material degradation.

  • 3 ◎ Quality Inspection

    • Post-shrinkage inspection: ensure no wrinkles or bubbles; insulation thickness deviation ≤±10%.
    • For irregular busbar joints, use custom tubing for segmented protection.

Packaging & Storage
  • ◎ Packaging: coiled or straight-cut, 50 meters per roll, sealed in moisture-proof bags.
    ◎ Storage conditions: -20℃~30℃, relative humidity <70%, avoid direct sunlight.

Key Advantages Summary
  • ● Compact design: reduces phase spacing, enhancing space efficiency.
  • ● Full environmental protection: moisture, dust, corrosion, and animal-resistant.
  • ● Safety compliance: UL, ROHS certified, ensuring electrical safety.
  • ● Easy installation: fast shrinkage, simplifying construction.
Performance Parameter
Test Item Test Method Test Value
Tensile Strength ASTM D638 ≥ 12MPA
Breakage Elongation ASTM D638 ≥ 300%
Tensile Strength after aging ASTM D638 ≥ 10MPA
Elongation after aging ASTM D638 ≥220%
Longitudinal Shrink Ratio ASTM D2671 ±5%
Dielectric Constant ASTM D2671 ≥ 18Ω.CM
Breakdown Strength ASTM D149 ≥ 25KV/MM
Volume Resistivity ASTM D257 10¹⁴Ω.CM
Volume Resistivity at 20℃ ASTM D257 10¹⁴Ω.CM
Oxygen Index ASTM D2863 ≥ 26%
Water Absorption ASTM D570 ≤0.2%
Density ASTM D792 1.25G/CM³
Eccentricity ASTM D792 30%
Fully Contraction Temperature Ratio ASTM D792 130±5℃
Test Item Test Method Test Value
Tensile Strength ASTM D638 ≥ 13MPA
Breakage Elongation ASTM D638 ≥ 450%
Tensile Strength after aging ASTM D638 ≥ 12MPA
Elongation after aging ASTM D638 ≥400%
Longitudinal Shrink Ratio ASTM D2671 ±5%
Dielectric Constant ASTM D2671 ≥ 18Ω.CM
Breakdown Strength ASTM D149 ≥ 25KV/MM
Volume Resistivity ASTM D257 10¹⁴Ω.CM
Volume Resistivity at 20℃ ASTM D257 10¹⁴Ω.CM
Oxygen Index ASTM D2863 ≥ 30%
Water Absorption ASTM D570 ≤0.2%
Density ASTM D792 1.25G/CM³
Eccentricity ASTM D792 30%
Fully Contraction Temperature Ratio ASTM D792 130±5℃
Product Specification Sheet
Specification Before Contraction After Contraction Packing Method
Inner Diameter(MM) Wall Thickness(MM) Inner Diameter(MM) Wall Thickness(MM)
LMPG-10-φ12/6 12±0.1 0.63±0.05 12±0.1 1.25±0.05 25M/Roll
LMPG-10-φ16/8 16±0.1 0.75±0.05 16±0.1 1.5±0.05 25M/Roll
LMPG-10-φ20/10 20±0.1 0.80±0.05 20±0.1 1.6±0.05 25M/Roll
LMPG-10-φ25/12.5 25±0.1 0.85±0.05 25±0.1 1.75±0.05 25M/Roll
LMPG-10-φ30/15 30±0.1 0.90±0.05 30±0.1 1.85±0.05 25M/Roll
LMPG-10-φ40/20 40±0.1 0.98±0.05 40±0.1 2.0±0.05 25M/Roll
LMPG-10-φ50/25 50±0.1 0.98±0.05 50±0.1 2.0±0.05 25M/Roll
LMPG-10-φ60/30 60±0.1 1.05±0.05 60±0.1 2.1±0.05 25M/Roll
LMPG-10-φ70/35 70±0.1 1.05±0.05 70±0.1 2.1±0.05 25M/Roll
LMPG-10-φ80/40 80±0.1 1.15±0.05 80±0.1 2.3±0.05 25M/Roll
LMPG-10-φ90/45 90±0.1 1.15±0.05 90±0.1 2.3±0.05 25M/Roll
LMPG-10-φ100/50 100±0.1 1.20±0.05 100±0.1 2.4±0.05 25M/Roll
LMPG-10-φ120/60 120±0.1 1.25±0.05 120±0.1 2.5±0.05 25M/Roll
LMPG-10-φ150/75 150±0.1 1.25±0.05 150±0.1 2.5±0.05 25M/Roll
LMPG-10-φ180/90 180±0.1 1.30±0.05 180±0.1 2.6±0.05 25M/Roll
Specification Before Contraction After Contraction Packing Method
Inner Diameter(MM) Wall Thickness(MM) Inner Diameter(MM) Wall Thickness(MM)
LMPG-35-φ30/15 30±0.1 1.46±0.05 30±0.1 3.0±0.05 20M/Roll
LMPG-35-φ40/20 40±0.1 1.46±0.05 40±0.1 3.0±0.05 20M/Roll
LMPG-35-φ50/25 50±0.1 1.46±0.05 50±0.1 3.2±0.05 20M/Roll
LMPG-35-φ60/30 60±0.1 1.60±0.05 60±0.1 3.2±0.05 20M/Roll
LMPG-35-φ70/35 70±0.1 1.60±0.05 70±0.1 3.2±0.05 20M/Roll
LMPG-35-φ80/40 80±0.1 1.60±0.05 80±0.1 3.2±0.05 20M/Roll
LMPG-35-φ90/45 90±0.1 1.60±0.05 90±0.1 3.2±0.05 20M/Roll
LMPG-35-φ100/50 100±0.1 1.60±0.05 100±0.1 3.2±0.05 20M/Roll
LMPG-35-φ120/60 120±0.1 1.65±0.05 120±0.1 3.3±0.05 20M/Roll
LMPG-35-φ150/75 150±0.1 1.65±0.05 150±0.1 3.3±0.05 20M/Roll
LMPG-35-φ180/90 180±0.1 1.65±0.05 180±0.1 3.3±0.05 20M/Roll

Make an free consultant

Your Name*

Phone Number

Country

Remarks*

reset
Frequently Asked Questions
What voltage ratings are available for this busbar heat shrink tubing?
This busbar heat shrink tubing is available in three voltage ratings: 1KV, 10KV, and 35KV. Each rating is engineered to meet the insulation demands of different electrical environments, from low-voltage distribution panels to high-voltage substation busbars.
What material is used and why is it suitable for high-voltage busbar insulation?
The tubing is made from Radiation-Crosslinked Polyolefin (XLPO). This material offers exceptional dielectric properties, including a breakdown voltage of ≥35KV/mm and insulation resistance of ≥10¹⁴ Ω·cm. The crosslinked structure also provides excellent resistance to heat, chemicals, moisture, and mechanical stress, making it ideal for demanding busbar insulation applications.
What is the correct temperature for shrinking the tubing during installation?
Shrinkage begins at approximately 80℃ and is fully completed at 120℃. For installation, it is recommended to use a heat gun or oven set to between 120℃ and 140℃. Care should be taken to avoid localized overheating, as this can degrade the material and compromise insulation performance.
Is this product compliant with international safety and environmental standards?
Yes. The tubing is certified to UL 224 (meeting VW-1 flame retardancy standards) and is compliant with ROHS 2.0, confirming it is lead-free and halogen-free. It also conforms to IEC 60811-1-1, supporting use in internationally regulated electrical installations and environmentally responsible projects.
What shrink ratios are available and how do I choose the right size?
The tubing is available in 2:1 and 3:1 shrink ratios, with radial shrinkage of ≥50%. To select the correct size, measure the outer diameter of the busbar after installation. Choose a tubing inner diameter that is approximately 20–30% larger than the busbar's largest cross-section to ensure complete, wrinkle-free coverage after shrinkage. Refer to the Product Specification Sheet for detailed size options.
How should the tubing be stored to maintain its performance?
The tubing should be stored at temperatures between -20℃ and 30℃, with relative humidity below 70%. It must be kept away from direct sunlight, heat sources, and strong UV exposure. Products are supplied in sealed moisture-proof bags in 50-meter rolls (coiled or straight-cut) to preserve material integrity before use.