Leave Your Message
China Silicone Cold Shrink Tube Factory - High-Performance Cable Insulation Suppliers
Hot Products

China Silicone Cold Shrink Tube Factory - High-Performance Cable Insulation Suppliers

,

Product Overview

,

Introducing high-quality silicone cold shrink tubing, a premier solution for cable splicing and termination insulation in challenging environments. Also referred to as power cable silicone cold shrink tubing or high-expansion ratio silicone rubber cold shrink tubing, our product is manufactured in China from superior Room Temperature Vulcanized (RTV-silicone rubber utilizing advanced platinum-cured technology. This tubing comes pre-expanded on a removable support core for easy installation. By simply pulling the core, the tubing quickly shrinks back onto the cable or joint, leveraging its remarkable elastic memory to create a permanent, reliable seal without any need for flames, heat guns, or sealing tapes. As one of the leading suppliers of silicone cold shrink tubing, our factory ensures top-notch quality and performance, making our product an essential accessory for any electrical application.

,
  • Texture of Material Silicon rubber
  • Hardness(Shore C) 40±5°
  • Density(g/cm³) 1.2±1
  • Elongation at Break(%) ≥500

Product Features
  • 🔵 Cold Shrink Installation, Convenient & Safe

    Eliminates traditional heat-shrink methods. Installation requires no special heating equipment or open flame, simplifying and speeding up the process while removing fire hazards. Ideal for explosive atmospheres or confined spaces.

  • 🔵 Exceptional Elasticity & Radial Pressure

    The tubing possesses strong resilience and constant radial contraction force, ensuring a tight seal remains intact despite cable thermal expansion/contraction or vibration, providing long-term, stable moisture and water resistance.

  • 🔵 Extreme Temperature Range & Superior Weather Resistance

    Continuous operating temperature range from -60℃ to 200℃, with higher short-term tolerance. The silicone material offers excellent resistance to natural aging, UV radiation, ozone, and salt spray corrosion, ensuring long-term stability in extreme conditions like frigid zones, humidity, coastal areas, and industrial pollution.

  • 🔵 High Insulation Reliability & Mechanical Protection

    The material provides high insulation resistance and dielectric strength, suitable for power cable systems up to 35KV. It also features excellent tear resistance and puncture resistance; a small cut on the surface will not propagate easily, offering reliable mechanical protection.

  • 🔵 Adaptable Shrink Ratio

    With an expansion ratio up to approximately 4:1, a single tube size can fit connectors within a range of outer diameters, simplifying inventory and enhancing application flexibility.

Product Specifications & Parameters

◎ Material: Specially formulated high-purity RTV-2 Silicone Rubber (Platinum cured).
◎ Standard Color: Black (other colors customizable upon request).
◎ Applicable Outer Diameter Range: Φ1mm to Φ70mm (or larger, customizable).
◎ Pre-shrink/Recovered Inner Diameter: Determined by model, various sizes available.
◎ Continuous Operating Temperature: -60℃ ~ +200℃.
◎ Hardness: 30-80 Shore A (typical ~40A).
◎ Rated Voltage: For power cable systems up to 35KV.
◎ Shrink Ratio: Up to approximately 4:1.
◎ Certifications: Complies with IEEE, IEC, GB, and other international/national standards. ROHS compliant.

Primary Application Fields
  • ◎ Power Transmission & Distribution Systems: Insulation and moisture sealing for terminations and joints of medium/low voltage power cables up to 35KV, especially for substations, power distribution cabinet, and outdoor overhead lines.
    ◎ Communications & Network Infrastructure: Waterproof and moisture-proof sealing for communication base station connectors, CATV connectors, and fiber optic splice closures.
    ◎ Rail Transit & Tunnel Engineering: Protection for cable and signal line joints in subway and high-speed rail tunnels, meeting low-smoke zero-halogen and long-term reliability requirements.
    ◎ New Energy & Industrial Sectors: Cable connections in wind and solar power plants, equipment cable sealing in chemical plants, mines, and other heavily polluted, high-humidity environments.
    ◎ Construction & Municipal Engineering: Insulation and protection for cable joints in building wiring, urban grid renovation, and street lighting systems.

Product Application 1
Product Application 2
Product Application 3
Installation & Usage Guide
  • ◎ Preparation:
    • Ensure the cable joint is properly prepared, with a clean, dry, and smooth surface free of burrs. Verify the cold shrink tubing size matches the cable outer diameter.

    ◎ Installation Steps:
    • Slide the cold shrink tubing over the cable and position it at the desired sealing location.
    • Evenly pull the internal support core (or plastic strip) in the direction indicated.
    • Observe the tubing shrinking uniformly from one end until it tightly encapsulates the cable joint.
    • After complete shrinkage, check that both ends of the tubing are properly seated, forming uniform skirt-like seals.

Technical Parameter

Texture of material

Silicon Rubber

Hardness (Shore C)

40±5°

Density (g/cm³)

1.2±1

Elongation at break (%)

≥500

Tensile strength (MPa)

≥8

Tear strength (KN/m)

≥30

200% fixed extension permanent transformer (%)

≤9.4

Volume resistivity (Ω/cm)

9×1016

Density (KG/cm3)

1.13

Breakdown strength (kV/mm)

20KV/mm

Product Specifications

Withstand Voltage Level

Applicable Cable Section (mm²)

Inner Diameter A

Wall Thickness C

Inner Diameter Range After Expansion

mm

mm

mm
Min.

mm
Max.

1KV

25-50

7

2

20

28

70-120

9

2

26

36

150-240

13

2

34

52

300-400

17

2

42

68

10KV

25-50

12

2.5

34

48

70-120

15

2.5

37

60

150-240

18

2.5

42

72

300-400

21

2.5

46

84

35KV

50-95

22

3

55

88

120-185

25

3

60

100

240-400

28

3

65

112

500-630

30

3

70

120

Note
⚠ All above data are common values only, excluding customized sizes. Special colors and packages can be made as per customization.
Make a Free Consultant

Your Name*

Phone Number

Country

Remarks*

reset
Frequently Asked Questions (FAQ)
Q What is cold shrink tubing and how does it differ from heat shrink tubing?
Cold shrink tubing is pre-expanded and supported by an internal plastic core. During installation, the core is removed and the tube contracts around the cable without any heat source. Unlike heat shrink tubing, no open flame, heat gun, or special equipment is needed, making it safer, faster, and suitable for hazardous environments.
Q What voltage levels is the cold shrink silicone tubing rated for?
The cold shrink silicone tubing is suitable for power cable systems up to 35KV, covering 1KV, 10KV, and 35KV voltage levels with different wall thickness and inner diameter specifications to match various cable cross-sections.
Q What is the operating temperature range of this silicone cold shrink tubing?
The tubing supports a continuous operating temperature range of -60℃ to +200℃, making it suitable for extreme environments including frigid zones, high-temperature industrial settings, coastal areas, and heavily polluted regions.
Q Can the cold shrink tubing be customized in size or color?
Yes. The standard color is black, but other colors are available upon request. The applicable outer diameter ranges from Φ1mm to Φ70mm or larger, with custom sizes available. Special packaging can also be arranged based on customer requirements.
Q What certifications does the product comply with?
The cold shrink silicone tubing complies with IEEE, IEC, GB, and other international and national standards. It is also ROHS compliant, ensuring it meets global environmental and safety requirements.
Q In which industries and applications can cold shrink silicone tubing be used?
It is widely used across power transmission and distribution, communications and network infrastructure, rail transit and tunnel engineering, new energy sectors (wind and solar), chemical and mining industries, as well as construction and municipal engineering — anywhere reliable cable insulation, waterproofing, and mechanical protection are required.