+86-17688612661 China ISO13485 Medical-Grade Silicone Tube Factory - Trusted Suppliers for Safe and Biocompatible Solutions
- ◎ Superior Biocompatibility & Certification Complies with ISO13485 (Biological Evaluation of Medical Devices) standards. Undergoes rigorous testing to ensure it does not cause cytotoxicity, sensitization, or irritation.
- ◎ Excellent Physical & Temperature Resistance Operates stably from -60℃ to 220℃. Highly transparent, flexible, and resistant to repeated kinking and aging.
- ◎ Stable Chemical & Electrical Properties Resistant to a wide range of bodily fluids, pharmaceuticals, and disinfectants. Excellent electrical insulation performance.
◎ Material: High-purity platinum-cured silicone rubber.
◎ Standard Color: High transparency (custom colors available upon request).
◎ Inner Diameter Range: Various sizes from small to large bore, customizable per drawings.
◎ Process: Produced via batch process for high transparency and tear resistance.
| Item | Parameter | |||
| (Shore A)(Hardness) | 40A±5A | 50A±5A | 60A±5A | 70A±5A |
| MPa(Kg/cm²) Tensile strength | ≧8.0 | ≧7.0 | ≧7.0 | ≧8.0 |
| Elongation | ≧500% | ≧500% | ≧400% | ≧300% |
| kN/m(kgf/cm) Tear strength | ≧18 | ≧25 | ≧25 | ≧40 |
| Ω·m(Ω·cm) Physical resistivity | ≧2×10¹⁴ | ≧2×10¹⁴ | ≧2×10¹⁴ | ≧2×10¹⁴ |
| KV/mm Dielectric strength | ≧20 | ≧20 | ≧20 | ≧20 |
| Use temperature range | -50~+200 | -50~+200 | -50~+200 | -50~+200 |
| Aging condition 200°C | No cracking at 4h | No cracking at 4h | No cracking at 4h | No cracking at 4h |
| Breakdown strength | 20kv/mm | 20kv/mm | 20kv/mm | 20kv/mm |
| Ozone resistance | flawless | flawless | flawless | flawless |
Primary Application Fields
◎ Automotive Industry: Fuel lines, brake lines, turbocharger hoses, coolant systems, and air intake systems.
◎ Industrial Machinery: Hydraulic and pneumatic systems, chemical transfer lines, food processing equipment (e.g., beverage filling lines), and pharmaceutical machinery.
◎ Aerospace & Defense: Aircraft fuel systems, hydraulic lines, and environmental control systems.
◎ Renewable Energy: Solar thermal systems, wind turbine cooling systems, and geothermal applications.
◎ Heavy Equipment & Mining: Excavator hydraulic hoses, mining slurry transfer lines, and dust extraction systems.
Usage Precautions & Maintenance
◎ Installation & Connection: Use medical-grade clamps or quick-connect fittings. Avoid over-stretching or twisting.
◎ Cleaning & Sterilization: Supports autoclaving (steam sterilization), gamma irradiation, and ethylene oxide sterilization. Can be cleaned with water, alcohol, or medical-grade detergents.
◎ Storage Conditions: Store in a cool, dry, ventilated place away from direct sunlight and sharp objects.
◎ Compatibility Testing: Conduct compatibility tests before use with strong acids, alkalis, or solvents.
| Specifications | Wall thickness Standard 0.5–0.9 |
Wall thickness Standard 1.0–1.9 |
Wall thickness Standard 2.0–2.9 |
Wall thickness Standard 3.0–3.9 |
Wall thickness Standard 4.0–5.0 |
|||||
| ID tol. | WT tol. | ID tol. | WT tol. | ID tol. | WT tol. | ID tol. | WT tol. | ID tol. | WT tol. | |
| Φ0.4 | ±0.1 | ±0.1 | ±0.1 | ±0.15 | - | - | - | - | - | - |
| Φ0.5 | ±0.1 | ±0.1 | ±0.1 | ±0.15 | - | - | - | - | - | - |
| Φ0.6 | ±0.1 | ±0.1 | ±0.1 | ±0.15 | - | - | - | - | - | - |
| Φ0.7 | ±0.1 | ±0.1 | ±0.1 | ±0.15 | - | - | - | - | - | - |
| Φ0.8 | ±0.1 | ±0.1 | ±0.1 | ±0.15 | - | - | - | - | - | - |
| Φ1.0 | ±0.1 | ±0.1 | ±0.1 | ±0.15 | ±0.1 | ±0.2 | ±0.1 | ±0.2 | - | - |
| Φ1.2 | ±0.1 | ±0.1 | ±0.1 | ±0.15 | ±0.1 | ±0.2 | ±0.1 | ±0.2 | - | - |
| Φ1.5 | ±0.1 | ±0.1 | ±0.1 | ±0.15 | ±0.1 | ±0.2 | ±0.1 | ±0.2 | - | - |
| Φ2.0 | ±0.1 | ±0.1 | ±0.1 | ±0.15 | ±0.1 | ±0.2 | ±0.1 | ±0.2 | ±0.2 | ±0.25 |
| Φ2.5 | ±0.1 | ±0.1 | ±0.1 | ±0.15 | ±0.1 | ±0.2 | ±0.1 | ±0.2 | ±0.2 | ±0.25 |
| Φ3.0 | ±0.1 | ±0.1 | ±0.1 | ±0.15 | ±0.1 | ±0.2 | ±0.2 | ±0.2 | ±0.2 | ±0.25 |
| Φ3.5 | ±0.1 | ±0.1 | ±0.1 | ±0.15 | ±0.1 | ±0.2 | ±0.2 | ±0.2 | ±0.2 | ±0.25 |
| Φ4.0 | ±0.1 | ±0.1 | ±0.1 | ±0.15 | ±0.1 | ±0.2 | ±0.2 | ±0.2 | ±0.2 | ±0.25 |
| Φ4.5 | ±0.1 | ±0.1 | ±0.1 | ±0.15 | ±0.1 | ±0.2 | ±0.2 | ±0.2 | ±0.2 | ±0.25 |
| Φ5.0 | ±0.1 | ±0.1 | ±0.1 | ±0.15 | ±0.1 | ±0.2 | ±0.2 | ±0.2 | ±0.2 | ±0.25 |
| Φ5.5 | ±0.1 | ±0.1 | ±0.1 | ±0.15 | ±0.1 | ±0.2 | ±0.2 | ±0.2 | ±0.2 | ±0.25 |
| Φ6.0 | ±0.15 | ±0.1 | ±0.15 | ±0.15 | ±0.15 | ±0.25 | ±0.2 | ±0.25 | ±0.25 | ±0.25 |
| Φ6.5 | ±0.15 | ±0.1 | ±0.15 | ±0.15 | ±0.15 | ±0.25 | ±0.2 | ±0.25 | ±0.25 | ±0.25 |
| Φ7.0 | ±0.15 | ±0.1 | ±0.15 | ±0.15 | ±0.15 | ±0.25 | ±0.2 | ±0.25 | ±0.25 | ±0.25 |
| Φ7.5 | ±0.15 | ±0.1 | ±0.15 | ±0.15 | ±0.15 | ±0.25 | ±0.2 | ±0.25 | ±0.25 | ±0.25 |
| Φ8.0 | ±0.2 | ±0.1 | ±0.2 | ±0.1 | ±0.2 | ±0.25 | ±0.2 | ±0.25 | ±0.25 | ±0.3 |
| Φ8.5 | ±0.2 | ±0.1 | ±0.2 | ±0.15 | ±0.2 | ±0.25 | ±0.2 | ±0.3 | ±0.25 | ±0.3 |
| Φ9.0 | ±0.2 | ±0.1 | ±0.2 | ±0.15 | ±0.2 | ±0.25 | ±0.2 | ±0.3 | ±0.25 | ±0.3 |
| Φ9.5 | ±0.2 | ±0.1 | ±0.2 | ±0.15 | ±0.2 | ±0.25 | ±0.2 | ±0.3 | ±0.25 | ±0.3 |
| Φ10.0 | ±0.2 | ±0.1 | ±0.2 | ±0.2 | ±0.2 | ±0.3 | ±0.25 | ±0.3 | ±0.25 | ±0.3 |
| Φ11.0 | ±0.3 | ±0.15 | ±0.3 | ±0.2 | ±0.3 | ±0.3 | ±0.3 | ±0.35 | ±0.3 | ±0.35 |
| Φ12.0 | ±0.3 | ±0.15 | ±0.3 | ±0.2 | ±0.3 | ±0.3 | ±0.3 | ±0.35 | ±0.3 | ±0.35 |
| Φ13.0 | ±0.3 | ±0.15 | ±0.3 | ±0.2 | ±0.3 | ±0.3 | ±0.3 | ±0.35 | ±0.3 | ±0.35 |
| Φ14.0 | ±0.3 | ±0.15 | ±0.3 | ±0.2 | ±0.3 | ±0.3 | ±0.3 | ±0.35 | ±0.3 | ±0.35 |
| Φ15.0 | ±0.3 | ±0.15 | ±0.3 | ±0.2 | ±0.3 | ±0.3 | ±0.3 | ±0.35 | ±0.3 | ±0.35 |
| Φ16.0 | ±0.4 | ±0.15 | ±0.4 | ±0.25 | ±0.4 | ±0.35 | ±0.45 | ±0.35 | ±0.45 | ±0.35 |
| Φ17.0 | ±0.4 | ±0.15 | ±0.4 | ±0.25 | ±0.4 | ±0.35 | ±0.45 | ±0.35 | ±0.45 | ±0.35 |
| Φ18.0 | ±0.4 | ±0.15 | ±0.4 | ±0.25 | ±0.4 | ±0.35 | ±0.45 | ±0.35 | ±0.45 | ±0.35 |
| Φ19.0 | ±0.5 | ±0.15 | ±0.5 | ±0.25 | ±0.5 | ±0.35 | ±0.45 | ±0.35 | ±0.45 | ±0.35 |
| Φ20.0 | ±0.5 | ±0.15 | ±0.5 | ±0.25 | ±0.5 | ±0.35 | ±0.5 | ±0.35 | ±0.5 | ±0.35 |
| Specifications | Wall thickness Standard 0.5–0.9 |
Wall thickness Standard 1.0–1.9 |
Wall thickness Standard 2.0–2.9 |
Wall thickness Standard 3.0–3.9 |
Wall thickness Standard 4.0–5.0 |
|||||
| ID tol. | WT tol. | ID tol. | WT tol. | ID tol. | WT tol. | ID tol. | WT tol. | ID tol. | WT tol. | |
| Φ21.0 | ±0.5 | ±0.15 | ±0.5 | ±0.25 | ±0.5 | ±0.35 | ±0.5 | ±0.35 | ±0.5 | ±0.35 |
| Φ22.0 | ±0.5 | ±0.15 | ±0.5 | ±0.25 | ±0.5 | ±0.35 | ±0.5 | ±0.35 | ±0.5 | ±0.35 |
| Φ23.0 | ±0.5 | ±0.15 | ±0.5 | ±0.25 | ±0.5 | ±0.35 | ±0.5 | ±0.35 | ±0.5 | ±0.35 |
| Φ24.0 | ±0.5 | ±0.15 | ±0.5 | ±0.25 | ±0.5 | ±0.35 | ±0.5 | ±0.35 | ±0.5 | ±0.35 |
| Φ25.0 | ±0.5 | ±0.15 | ±0.5 | ±0.25 | ±0.5 | ±0.35 | ±0.3 | ±0.4 | ±0.5 | ±0.45 |
| Φ26–30 | ±0.8 | ±0.2 | ±0.8 | ±0.25 | ±0.8 | ±0.4 | ±0.8 | ±0.4 | ±0.8 | ±0.45 |
| Φ31–35 | ±1.5 | ±0.2 | ±1.5 | ±0.25 | ±1.5 | ±0.4 | ±1.5 | ±0.5 | ±1.5 | ±0.45 |
| Φ36–40 | ±1.5 | ±0.2 | ±1.5 | ±0.25 | ±1.5 | ±0.4 | ±1.5 | ±0.5 | ±1.5 | ±0.45 |
| Φ41–45 | ±1.8 | ±0.2 | ±1.8 | ±0.25 | ±1.8 | ±0.4 | ±1.8 | ±0.5 | ±1.8 | ±0.45 |
| Φ46–50 | ±1.8 | ±0.2 | ±1.8 | ±0.25 | ±1.8 | ±0.4 | ±1.8 | ±0.5 | ±1.8 | ±0.45 |
| Φ51–55 | ±2.5 | ±0.25 | ±2.5 | ±0.3 | ±2.5 | ±0.5 | ±2.5 | ±0.5 | ±2.5 | ±0.45 |
| Φ56–60 | ±3.0 | ±0.3 | ±3.0 | ±0.5 | ±13.0 | ±0.5 | ±3.0 | ±0.5 | ||
| Φ61–65 | ±4.0 | ±0.3 | ±4.0 | ±0.5 | ±4.0 | ±0.5 | ±4.0 | ±0.5 | ||
| Φ66–70 | ±5.0 | ±0.4 | ±5.0 | ±0.5 | ±5.0 | ±0.5 | ±5.0 | ±0.5 | ||
| Φ71–75 | ±6.0 | ±0.4 | ±6.0 | ±0.5 | ±6.0 | ±0.55 | ±6.0 | ±0.6 | ||
-
What certifications does this platinum-cured silicone tubing comply with?This silicone tubing complies with ISO13485 (Biological Evaluation of Medical Devices) standards. It undergoes rigorous testing to confirm it does not cause cytotoxicity, sensitization, or irritation, making it suitable for medical and pharmaceutical applications.
-
What is the operating temperature range of this silicone tubing?The silicone tubing operates stably from -60℃ to 220℃ (-76°F to 428°F). It maintains flexibility and integrity across this entire range and is resistant to aging under both high-temperature and low-temperature conditions.
-
Can the inner diameter and color be customized?Yes. The standard color is high transparency, but custom colors are available upon request. Inner diameter sizes range from small to large bore and can be fully customized according to customer drawings and technical requirements.
-
How should this silicone tubing be cleaned and sterilized?The tubing supports multiple sterilization methods including autoclaving (steam sterilization), gamma irradiation, and ethylene oxide sterilization. For routine cleaning, it can be washed with water, alcohol, or medical-grade detergents without compromising material integrity.
-
What industries and applications is this silicone tubing suitable for?This tubing is widely used across the automotive industry (fuel lines, coolant systems), industrial machinery (hydraulic and pneumatic systems), aerospace and defense, renewable energy (solar thermal and wind turbine cooling), food and pharmaceutical processing, as well as heavy equipment and mining applications.
-
What are the recommended storage conditions and installation precautions?Store the tubing in a cool, dry, well-ventilated place away from direct sunlight and sharp objects. During installation, use medical-grade clamps or quick-connect fittings and avoid over-stretching or twisting. Before use with strong acids, alkalis, or solvents, always conduct compatibility tests to ensure suitability.